UNO-1019PXA 200MHZ, 6 4 M B R A M , 2 x L A N , 4 x C O M Universal Network ControllerUser
UNO-1019 User Manual 2Chapter 1 Overview1.1 IntroductionAdvantech’s UNO-1019 is a RISC-grade embedded platform that offers 2 LANs, 4 serial ports an
3 Chapter 1 1.3 Hardware SpecificationsGeneral • Certifications CE, FCC Class A• Dimensions (W*H*D) 46 x 162 x 126 mm• Enclosure ABS+PC with sol
UNO-1019 User Manual 4Digital I/ODigital In 2 Digital InputDry Contact Logic level 0 : Open Logic level 1 : CloseWet ContectLogic level 0: +3V m
5 Chapter 1 1.4 Chassis DimensionsFigure 1.1: UNO-1019 Top View DimensionsFigure 1.2: UNO-1019 Side View Dimensions
UNO-1019 User Manual 6Figure 1.3: UNO-1019 Front View DimensionsFigure 1.4: UNO-1019 Bottom View Dimensions
2CHAPTER 2InstallationIn this chapter, you will be given an overview of the UNO-1019 hardware installation procedures.Sections include:• Overview:•
UNO-1019 User Manual 8Chapter 2 Installation2.1 OverviewFigure 2.1: UNO-1019 OverviewItem Description1 Serial Port2 Networking port3LED4 CompactFlas
9 Chapter 2 2.2 LEDsLEDs to display the power, network, serial and programmable LED status are located on the front panel of UNO-1019, and each of t
UNO-1019 User Manual 102.4 Serial Connections2.4.1 Serial Type SelectionUNO-1019 provides 4 serial Com ports, COM1 & COM2 provide RS-232, and COM
11 Chapter 2 2.4.2 Enable ModeYou could set the Enable mode by using DIP switches (S10). If the switches are set to "Off", the driver autom
UNO-1019 User Manual iiCopyrightThe documentation and the software included with this product are copy-righted 2006 by Advantech Co., Ltd. All rights
UNO-1019 User Manual 12Refer to the figure and table below for COM1 & COM2 descriptions. COM1 & COM2 Pin Assignments Pin RS-2321 DCD2RxD3TxD4D
13 Chapter 2 Refer to the figure and table below for COM3 & COM4 descriptions. 2.5 Power ConnectionsUNO-1019 supports +10 ~ 30 VDC power inputs.
UNO-1019 User Manual 142.6 Digital Input/OutputThere are two digital inputs and outputs for UNO-1019. Figure 2.5: Digital I/O Pin AssignmentsYou can
15 Chapter 2 Figure 2.6: Digital Input Connection (Dry Contact)Figure 2.7: Digital Input Connection (Wet Contact)
UNO-1019 User Manual 16UNO-1019 also provides digital outputs connection, please refer below figure shows how to connect digital output function. (The
17 Chapter 2 2.8 MountingUNO-1019 supports two different mounting methods: Panel & DIN-rail.2.8.1 Panel MountingUNO-1019 can be wall mounted by
UNO-1019 User Manual 18Then, screw the whole device to the wall.Figure 2.10: Attach UNO-1019 to the Wall
19 Chapter 2 2.8.2 DIN-rail MountingYou can also mount UNO-1019 on a standard DIN-rail by below steps.First, pull down the kit in the back of UNO-101
UNO-1019 User Manual 20Then, hang the UNO-1019 to the DIN-rail with angle of inclination. Figure 2.12: Installation to DIN -rail Step 2
21 Chapter 2 Put the UNO-1019 at a right angle with the Din-rail. The grounding spring in the back should be flush with the aluminum rail. Then pull
iiiProduct Warranty (2 years)Advantech warrants to you, the original purchaser, that each of its prod-ucts will be free from defects in materials and
UNO-1019 User Manual 22
2CHAPTER 3Initial SetupThis chapter shows how to initialize the UNO-1019, sections include:Sections include:• Initial Procedure• Configure UNO-1019
UNO-1019 User Manual 24Chapter 3 Initial Setup3.1 Initial ProcedureThe UNO-1019 offers an easy setup feature: it takes four easy steps for your ini
25 Chapter 3 *actually you can set any IP address other than 10.0.0.1 and 10.0.0.2 from 10.0.0.3 to 10.0.0.255 . If you connected you computer and UN
UNO-1019 User Manual 26Choose the connected device in the list : After clicking “Connect” bottom, the configuration computer will con-nect with UNO-10
27 Chapter 3 Please go to the “Command Prompt” for network IP setting User can use “ipchange” command for IP change setting in command prompt mode. P
UNO-1019 User Manual 28If LAN1 of UNO-1019 will be set as DHCP, the ipchange 1/1 will be used as set up command. If LAN2 of the UNO-1019 will be set a
29 Chapter 3 Press “Enter”, the remote display will show the following message.Wait for the “Saving Registry Done” to make sure the IP change settin
UNO-1019 User Manual 30
2CHAPTER 4Advanced ApplicationsThis Chapter will provide detailed explanations of the UNO-1019’s Advanced ApplicationsSections include:• Inserting a
UNO-1019 User Manual ivDeclaration of ConformityCEThis product has passed the CE test for environmental specifications when shielded cables are used f
UNO-1019 User Manual 32Chapter 4 Advanced Applications4.1 Inserting a CompactFlash Card The procedure for installing a CompactFlash card into the UN
33 Chapter 4 ActiveSync Connection The tool is used for the application program on-line programming/debug requirement. User has to install the Micros
UNO-1019 User Manual 341. Click the icon “Make New Connection”Select the connection type: Direct Connection, then press Next
35 Chapter 4 2. Choose the COM port of UNO-1019. 3. Press Start / Settings / Control Panel, and then “PC Connection”.4. Click Change button to choose
UNO-1019 User Manual 36Step 4 : Setting Up the Communication Environment of the Host1. Double click the icon ActiveSync.2. Select File/Connection Sett
37 Chapter 4 3. Configure the connection settings as below.4. After you configure the connection setting, it will show the below dialog window when y
UNO-1019 User Manual 385. Press Start/ Run of UNO-1019; enter the \windows\repllog.exe in the command line of and press OK buttonNote: Don’t click Ne
39 Chapter 4 6. Now, press the Next button in the “Get Connected” dialog in the host. It will build the connection between UNO-1019 and host.7. If th
UNO-1019 User Manual 408. If the connection between UNO-1019 and the host has been established, you will see below message in the host.Select No,
41 Chapter 4 9. Press Explore button in Microsoft ActiveSync window, it will pop up the Mobile Device window to display the file resources and inform
vSafety Instructions1. Read these safety instructions carefully.2. Keep this User's Manual for later reference.3. Disconnect this equipment from
UNO-1019 User Manual 42Begin Transferring Files from the PC to UNO-1019Double click “My Computer” in “Mobile Device” for file translation.4.3 Remote
43 Chapter 4 Dial-up Configuration 1. Press start of task bar of window system and select “Settings” / “Networking and Dial-up Connections”2. Double
UNO-1019 User Manual 443. Setup the device according to the specification of the modem and press Next >.
45 Chapter 4 Enter the telephone number in the “Phone Number” window. Press Finish button to complete the dial-up configuration.4. Press start of tas
UNO-1019 User Manual 465. Press Dialing Patterns button in the Dialing Properties window. Edit the dialing pattern for each type of call to change how
47 Chapter 4 6. Double click My Connection and press Connection button to build a PPP connection.Dial-in Configuration1. Press start of task bar of w
UNO-1019 User Manual 482. Double click the RAS Server icon from Control Panel. 3. Select the “General” tab under “Advantech RAS Server Configura-tion”
49 Chapter 4 4. Select the “Input Lines” tab under “Advantech RAS Server Config-uration”. Click Add button to setup the input line according to the a
UNO-1019 User Manual 506. Select the “Logon Security” tab under “Advantech RAS Server Configuration”. Add a new account for remote access services. 7.
51 Chapter 4 4.4 Autorun Configuration NoteThis document introduces how to execute applications automatically when you boot UNO-1019 up.Autorun Conf
UNO-1019 User Manual vi15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -20° C (-4° F) OR ABOVE 60° C (140
UNO-1019 User Manual 52
53 Chapter 4 3. Click on the “Program Path” bottom for selecting the program for Auto-Run setting..Please choose the program then press “OK”.
UNO-1019 User Manual 544. Click on the “Add” bottom to set the program for Auto-Run action.The UNO Configuration Utility will add the selected program
55 Chapter 4 4.5 Application Development ProcedureUNO-1019 provides Software Development Kit (SDK) and a built-in runtime library; you can use your
UNO-1019 User Manual 568. Select “UNO-1019” in the main window of Visual C++ .
57 Chapter 4 9. After you complete above configuration procedure, you can start to develop your application. Press “Build”/ “Build xxx.exe” to com-pi
UNO-1019 User Manual 58How to Use the Control CodeThere are 6 control codes for the operation codes in the WDT driver.1. IOCTL _WDT_ENABLE:Enable the
59 Chapter 4 4. IOCTL_WDT_GETTIMEOUT:Get the Watchdog timeout value.lpInBuffer: unused.nInBufferSize: unused.lpOutBuffer: The DWORD pointer to your W
UNO-1019 User Manual 60DeviceIOControlThis function sends a control code directly to a specified device driver, causing the corresponding device to pe
61 Chapter 4 [out] Long pointer to a buffer that receives the output data for the opera-tion. This parameter can be NULL if the dwIoControlCode param
vii Table of ContentsContentsChapter 1 Overview ... 21.1 Introduction ...
UNO-1019 User Manual 62#define IOCTL_WDT_REBOOT CTL_CODE(FILE_DEVICE_UNKNOWN, 0x905, METHOD_BUFFERED, FILE_ANY_ACCESS)HANDLE m_hWDT=NULL;TCHAR szClass
63 Chapter 4 While (1) {// do your job here.Sleep(8000);DeviceIoControl(m_hWDT, IOCTL_WDT_STROBE, NULL,0, NULL, 0, &dwTemp, NULL);}DeviceIoContro
UNO-1019 User Manual 642. ADV_IOCTL_WRITE_DO:Write value out the Digital Output.lpInBuffer : The BYTE pointer to the DO value that is requesting to wr
65 Chapter 4 6. ADV_IOCTL_TURN_ON_LED2:Turn LED2 on.lpInBuffer :unused.nInBufferSize: unused.lpOutBuffer: unused.nOutBufferSize: unused.7. ADV_IOCTL_
UNO-1019 User Manual 6610. IOCTL_PLAY_BUZZER:Make the buzzer start beeping.lpInBuffer : The DWORD pointer to the number of mini-seconds to play.nInBuf
67 Chapter 4 Parameters:. hDevice[in] Handle to the device that is to perform the operation. Call the Create-File function to obtain a device handle.
UNO-1019 User Manual 68Nonzero indicates success. Zero indicates failure. To get extended error information, call GetLastError.Examples#define ADV_IOC
69 Chapter 4 CTL_CODE(FILE_DEVICE_UNKNOWN, 0x950, METHOD_BUFFERED, FILE_ANY_ACCESS)#define IOCTL_STOP_BUZZER CTL_CODE(FILE_DEVICE_UNKNOWN, 0x951, MET
UNO-1019 User Manual 70 dwGot |= 0x01; // set Dout_0 high dwGot |= 0x02; // set Dout_1 high printf("Set Dout_0 high, Set D
71 Chapter 4 DeviceIoControl(hDev, ADV_IOCTL_TURN_OFF_LED1, NULL, 0, NULL, 0, NULL, NULL); } if( dwGot & 0x02 ) {
UNO-1019 User Manual viii4.3 Remote Access Server Configuration ... 424.4 Autorun Configuration Note ...
UNO-1019 User Manual 724.6 Saving Your SettingsOnce you made changes for UNO-1019, you may need run RegSave.exe to save Windows CE system Registry t
73 Chapter 4 4.7.1 Network Administration Following steps introduces how to connect the UNO-1019 by standard browser, and configure the field-site UN
UNO-1019 User Manual 743. Connect to the UNO-1019 again, and the system will ask you to enter user name and password. After authorization, you will en
75 Chapter 4 Network SettingsChange IP information about the UNO-1019.1. Change device name Enter proper device name and press Submit button.Please M
UNO-1019 User Manual 76IPV6If you want to enable “IPV6”, please check “Enable IPV6” and press Submit button.System will ask you to restart UNO-1019, t
77 Chapter 4 Advanced Setting“Advanced setting” allows ports to be statically reserved and mapped.System will list all of the adapters present on the
UNO-1019 User Manual 78User Accounts“User Accounts” function allows you to add, modify and delete user accounts on this UNO-1019. "ADMIN" is
79 Chapter 4 2. Create a Group <2-A> Enter a group name in the “Create a new” field, and press Create.<2-B> If you want to choose which u
UNO-1019 User Manual 80<2-C> If you want to delete a group, please press Delete button behind the group name.FeaturesAllows configuration of adv
81 Chapter 4 4.7.2 File Server<A-1> Choose the folder in UNO-1019 you wish to share and then enter a share name then press “Submit”.<A-2>
2CHAPTER 1OverviewThis chapter gives background infor-mation on the UNO-1019. It shows you the UNO-1019 overview and specifica-tions.Sections include:
UNO-1019 User Manual 82Note: If you want to use password to protect UNO file server, please key in your ADMIN password, chossing "PWD Enabled&qu
83 Chapter 4 Creating a Network DiskWindows CE provides the command to enable remote network disk as a local disk.<Command>Usage: net us
UNO-1019 User Manual 842. Execute the blow command by local UNO-1019’s command prompt, and system will ask you to enter your user name, password and d
85 Chapter 4 If you want to delete this folder on UNO-1019 , you could execute the command as below<EX> net use UNO1019V1 \\nb940902\temp /user
UNO-1019 User Manual 86LogsUse Logs section to control what information about the FTP transactions is logged.
87 Chapter 4 FTP UsersUse FTP Users section to control access to the FTP server for each user. To add new user, please go to the “User Account” page.
UNO-1019 User Manual 88Virtual RootsYou can add/delete virtual roots to the FTP server. Virtual roots allow you map a physical directory to and direct
89 Chapter 4 4.7.4 Telnet ServerThe telnet server accepts telnet connections and allows the UNO-1019 to be configured remotely.Telnet Server Configur
UNO-1019 User Manual 904.7.5 Restart NetworkRestart for network change to take effect. To make the changes you have made take effect immediately, plea