User’s Manual RS-200-RT 2U Server
Chapter 1: Introduction The RS-200-RT is a 2U high, rack-mountable server for high-density Internet services. Engineered for Internet service pro
motherboards, flexibly configurable high capacity, high-speed hot-swappable SCSI storage devices, high-speed network interfaces and specially designed
1.1 Specifications 1.1.1 RS-200-RT-R3-R3 General Specification CPU Dual Intel Pentium !!! 1.13/1.26GHz Chipset Serverworks III LE chipset w/ 1
System and Environment Construction 19” Rack Mount, Heavy-duty steel chassis, 2U, front cover with key lock Cooling System 4 52-CFM cooling fans, to
Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI OS Linux, Free BSD 4.x, Win 2K/NT
1.1.2 RS-200-RT-R3-S6 General Specification CPU Dual Intel Pentium !!! 1.13/1.26GHz Chipset Serverworks III LE chipset w/ 133MHz FSB BIOS Award
System and Environment Construction 19” Rack Mount, Heavy-duty steel chassis, 2U, front cover with key lock Cooling System 4 52-CFM cooling fans, t
Storage Humidity 5~95% Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI OS Linux, F
1.1.3 RS-200-RT-S3-S6 General Specification CPU Dual Intel Pentium !!! 1.13/1.26GHz Chipset Serverworks III LE chipset w/ 133MHz FSB BIOS Award
System and Environment Construction 19” Rack Mount, Heavy-duty steel chassis, 2U, front cover with key lock. Cooling System 4 52-CFM cooling fans,
Copyright Notice This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make
Storage Humidity 5~95% Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI OS Linux, F
1.1.4 RS-200-RT-TB General Specification CPU Dual Intel Pentium !!! 1.13/1.26GHz Chipset Serverworks III LE chipset w/ 133MHz FSB BIOS Award Fl
System and Environment Construction 19” Rack Mount, Heavy-duty steel chassis Cooling System 4 52-CFM cooling fans, totally 208 CFM Controls Syste
Certifications FCC Class A, CE, UL, CUL, BSMI OS Win 2K/NT 4.0, Linux RS-200-RT User’s Manual 22
1.2 External Connection SCSI Connector: The serverboard provides a 68-pin Ultra-160 connector for extending SCSI storage devices. Dual USB
Printer Port Connector: The serverboard provides a 25-pin female centronic connector for LPT. The parallel port is a standard printer port that also s
1.3 Front Panel 1.3.1 RS-200-RF-R3-S6 and RS-200-RT-S3-S6 Please use a key in accessory box to unlock the front cover. Front Panel CD-ROM F
1.3.2 RS-200-RT-R3-R3 and RS-200-RT-TB Front Panel CD-ROM/DVD-ROM FDD Power Switch LEDs B-ID1 B-ID2 B-ID3 A-ID1 A-ID2
1.4 Rear Panel 64-bit PCI slot port 32-bit PCI slot port Power Supply RS-20
1.5 System Monitoring Fan status monitoring and alarm: To prevent system from overheating and damages, the CPU fans and other system fans can be mo
Adaptec is registered trademark of Adaptec Corporation. ATI is a trademark of ATI Technologies, Inc. Serverworks is a trademark of Serverwork
panel, and the buzzer will sound to alert. Even if the Alarm Reset button and the system mute are pressed, the red light from the Alarm LED will still
RS-200-RT User’s Manual 30
Chapter 2 System Placement and Installation 2.1 System Placement Power Supply Motherboard CD-ROM/ FDD
2.2 Motherboard Placement Northbridge RAID Module Connector DIMM Socket LAN Module SCSI Port (Ch-B)
The description of jumpers on the motherboard CN24-Power Bottom / PCI64 33/66MHz Jumper Function Remark 1-2 Close to Open Power On >0.5 Sec
J4-RTC CMOS Jumper setting Jumper Function 1-2 Closed RTC CMOS Active 2-3 Closed CMOS Clear JFREQ1 Ratio Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 R
2.3 SCSI Backplane Placement 2.3.1 SCA-2 SCSI Backplane CN10 CN8 CN9 CN3 CN1 CN4 CN7 CN5 CN6 Connector Des
2.3.2 Dual SCSI Channel Backplane Power Connector Power Connector CH-A SCSI I/P CH-B SCSI I/
2.4 Installing CPU The server has two Socket 370 CPU sockets that can accommodate Intel Tualatin CPUs as noted in the server specification table. T
Raise the retaining lever of CPU socket to a position perpendicular to the socket up. Orient the CPU to the socket correctly so that the
Product Warranty Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship
Lower the retaining lever so that the CPU locks in place and latch the arm to the side of the socket. Repeat this operation for the second C
2.5 Installing CPU Cooler Fan After a CPU has been installed, you will need to install the proper cooling device for the CPU. The server comes with t
Place the clip to hold the protrusion on the side of CPU socket. Place the clip to hold the protrusion on another side of CPU socket
CPU Cooler Fan installed. Please repeat the same procedure to install another CPU and CPU cooler fan. Please use extra caution when installing
2.6 Installing System Memory The serverboard has four 168-pin DIMM sockets for 3.3V Registered PC-133 compliant SDRAM with ECC. The approved SDRAM mo
Press the module into the socket so that it seats firmly in place and the retaining latches rotate upwards and seat them selves in the notches
2.7 Installing Add-on Card There are two expansion slots on the preinstalled riser card. It allows user to install up to 2 64bit/66MHz PCI add-on car
Fasten the bracket of the add-on card with screw. RS-200-RT User’s Manual 46
2.8 Installing LAN Module The server provides an optional LAN module for the third 10/100Mps LAN. You can buy the LAN module from your dealer near yo
2.9 Installing Zero Channel Hardware RAID Module The machine provides an inexpensive and optional hardware RAID solution without sharing extra PCI sl
1. Collect all the information about the problem encountered. For example, CPU speed, Advantech products used, other hardware and software used, etc.
2.10 Adding Disk Drives The RS-100/200-RT has preinstalled three/six hard disk drive bays, one slim-type CD-ROM or DVD-ROM (master mode only) and o
Hard Disk drive assembled Slide the cages of the HDD drive into HDD bays andmake HDD drive connectors connect the SCSIsockets on SCSI backplane clos
2.11 Installing Rail Slider RS-200-RT User’s Manual 51
RS-200-RT User’s Manual 52
Chapter 3 BIOS Setup Award BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration. This type of informati
Key Function Description Esc Jump to Exit menu or return to the main menu from sub-menu ↑or ↓ Move the cursor to the up or down between fields ← or →
3.2 Main Menu When the Setup program is accessed, the following screen appears. Move arrow keys to the appropriate place you will setup and press “En
3.2.1 Standard CMOS Features Choose the “Standard CMOS Features” option from main menu. The “Standard CMOS Features” allows users to configure system
IDE Primary Master: Move the highlight to the “IDE Primary Master” and enter to get the following screen. IDE HDD Auto-Detection: To auto-detect t
IDE Primary Master: [Auto/Manual/None] Access Mode: [Auto/Large/LBA/CHS] RS-200-RT User’s Manual 58
Packing List You should find the items listed below in the server package. If anything is missing or damaged, please consult with your vendor for res
IDE Primary Slave: Choose the option then get the following three items. IDE HDD Auto-Detection: To auto-detect the capacity, cylinder, head and sect
Drive A: Set the type of floppy drive installed by Page Up Key and Page Down. Halt On: Set system halt on when specified item occurs. The selection
3.2.2 Advanced BIOS Features Quick Power On Self Test (POST) [Enabled/Disabled]: Allows the system to skip certain tests while booting. This will d
Third Boot Device [Floppy/SCSI/CD-ROM/HDD/LAN/Disabled]: Select your boot device priority Boot Other Device [Enabled/Disabled]: Select your boot devi
Typematic Rate (Chars/Sec): BIOS accepts the following input values (characters/second) for typematic rate: 6, 8, 10, 12, 15, 20, 24 and 30. Typemati
3.2.3 Integrated Peripheral On-Chip Primary PCI IDE [Enabled/Disabled]: The system provides an onboard on-chipset PCI IDE controller that suppor
IDE Primary Master/Slave UDMA [Auto/Disabled] On-Chip Secondary PCI IDE [Enabled/Disabled] IDE Secondary Master/Slave PIO [Auto/Mode0/Mode 1-4] IDE
Onboard Serial Port 2 [Auto/Disable/(3F8/IRQ4)/(2F8/IRQ3)/(3E8/IRQ4)/(2E8/IRQ3)] The system has an On-board Super I/O chipset with 2 serial ports. Th
3.2.4 PnP/ PCI Configurations PnP OS Installed [Yes/No]: Select “Ye s” if you are using a Plug and Play enabled operating system. Select “No” if yo
automatically assigns them. PCI/VGA Palette Snoop [Disabled/Enabled]: Some display cards that are nonstandard VGA, such as graphics accelerators or
Contents Chapter 1 Introduction ------------------------------ 9 1.1 Specifications ------------------------------------ 11 1.2 External Connecti
3.2.5 Load Optimized Defaults The option allows you to load the optimized default values for each of the parameters on the Setup menus. When this o
3.2.6 Set Password The option allows you to set or change user password. To set the user password, press “Enter”. Type password and press “Enter”. Yo
3.2.7 Save & Exit Setup Once you finish your selection, choose the option to save the values you selected to CMOS RAM. The CMOS RAM is sustained
3.2.8 Exit without Saving The option should only be used if you do not want to save the changes you have made to the Setup program. If you have made
Chapter 4 Drivers Installation The servers support several Operating Systems including Microsoft Windows NT 4.0/ 2000, Linux 7.x, Free BSD 4.x and
4.1 Drivers for Windows NT 4.0 In the CD disc for Driver Bank, there are some options as below when running “Setup” or CD auto-run. VGA driver in
Installing SCSI driver for Windows NT 4.0 Driver Install during Windows NT Installation 1. CD-ROM Install: Boot from the CD-ROM of Win NT 4.0 and
Install LAN Driver Please go to the following subdirectory when system requests LAN driver during OS installation. rs100_200_rf\82559\LAN – Driv
4.2 Drivers for Windows 2000 VGA driver installation Please select the item “RS200-RT Drivers”. Please click “Install VGA driver
Adaptec I2O RAID Host Adapter Driver for Windows 2000 Driver setup during Windows 2000 Installation 1. CD-ROM Install: Boot from the CD-ROM and p
3.2 Main Menu -------------------------------------- 55 3.2.1 Standard CMOS Features ---------------- 56 3.2.2 Advanced BIOS Features ----------
4.3 Drivers for Red-Hat Linux 7.0/7.1 Adaptec I2O RAID Host Adapter Driver for Linux Red-Hat 7.0/7.1 1. Boot from CD-ROM, Insert floppy diskette
RS-200-RT User’s Manual 80
Appendix A Memory Approval List No Vendor Model Name Die Capacity 1 SMART SM572164574E63R SAMSUNG K4S640432D-TC75 128MB 2 SMART SM572324574E03R S
Appendix B. RAID Card Approval List No. Vendor Model Name 1 AMI MegaRAID Express 200 (Series 466) 2 AMI MegaRAID Express 500 (Series 475) 3 Mylex
Appendix D Safety Instructions D.1 English 1. Read these safety instructions carefully. 2. Keep this user’s manual for later reference. 3. Disconnect
service personnel. a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d
D.2 German- Wichtige Sicherheishinweise 1. Bitte lesen Sie Sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrau
elektrischen Schlag auslösen. 13. Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicep
Appendix E GEM 318 Driver Installation There are 1 or 2 GEM318 chips on SCSI backplane. The chips are used to detect SCSI HDD failure. Basical
RS-200-RT User’s Manual 8
Comments to this Manuals