EKI-4524RI 24-port 10/100TX + 2-port 100 Mini-GBIC Ethernet Switch with AC/DC Power Input and Wide Operating Temperature EKI-4524ARI 24-port 10/100T
Chapter 1 Overview 1.1 Introduction The EKI-4524RI/4524ARI is a cost-effective solution, which meets the high reliability requirements demanded b
1.2 Features • System Interface/Performance ¾ RJ-45 ports support Auto MDI/MDI-X Function ¾ 2 x 100Mbps SFP (mini-GBIC) ports supported for long dis
1.3 Specifications Communications IEEE Standard IEEE 802.3, 802.3u, 802.3x LAN 10/100Base-TX 100Base-FX Transmission Distance UTP: Up to 100m S
Environment Operating Temperature -40 ~ 75oC (-40 ~ 167oF) Operating Humidity 5 ~ 95% (non-condensing) Storage Temperature -40 ~ 85oC (-40 ~ 18
EKI-4524RI & ARI_User Manual 6 1.4 Packing List • 1 x EKI-4524RI/4524ARI Series Industrial Unmanage
7 Chapter2 Installation Sections include:
Chapter 2 Installation In this chapter, you will be given an overview of the EKI-4524RI/4524ARI hardware installation procedures. 2.1 LED Indicat
2.2 Dimensions (units: mm) Figure 2.1: EKI-4524RI Mechanical Dimensions Figure 2.2: EKI-4524ARI Mechanical Dimensions 9
2.3 Mounting 2.3.1 Rack mounting EKI-4524RI/4524ARI comes with a rack-mounted kit and can be mounted in an EIA standard size, 19-inch rack. The Sw
2.4 Network Connection The EKI-4524RI/4524ARI has 24 x RJ-45 ports that support connection to 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and hal
Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co., Ltd. All rights are reserved. Advantec
Figure 2.6: Transceiver Inserted Second, insert the fiber cable of LC connector into the transceiver. Figure 2.7: LC Connector to the Transc
To remove the LC connector from the transceiver, please follow the steps shown below: First, press the latches of the LC connector and pull it out f
2.6 Wiring the Power Input EKI-4524RI Power Input Wiring EKI-4524RI comes equipped with a 10-position cross screw terminal block on where power
EKI-4524ARI Power Input Wiring 1. Insert DC power wires into the contacts. Pin 5: Negative Pin 6: Positive Pin 3 & 4: P-Fail Contacts Pin 1 &
2.7 Wiring the Fail-Safe Alarm Contacts With a Normally Close circuit formed by wiring with an external power and an alarm device (a buzzer or a f
17 Troubleshooting CHAPTER
Chapter 3 Troubleshooting Verify that you are using the right power cord/adapter. Please don’t use a power adapter with DC outputs higher than the
19 Pin Assignment & Wiring
Appendix A Pin Assignments & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figu
21 Compatible SFP Transceivers
Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and wo
Appendix B Compatible SFP Transceivers The table below shows compatible SFP transceivers for EKI-4524RI/4524ARI. Item Brand Part Number Mode
Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipmen
Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment
Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid elec
vii Contents Contents Chapter 1 Overview...2 1.1
EKI-4524RI & ARI_User Manual viii
1 Chapter1 Overview Sections include: z Introduction z Fea
Comments to this Manuals