RS-100-RT User’s Manual 9 Chapter 1: Introduction The RS-100-RT is a 1U high, rack-mountable server for high-density Internet services. Enginee

Page 3

RS-100-RT User’s Manual 10 motherboards, flexibly configurable high capacity, high-speed hot -swappable SCSI storage devices, high-speed network inter

Page 4

RS-100-RT User’s Manual 11 1.1 Specifications 1.1.1 RS-100-RT-S3-S3 General Specification CPU Dual Intel Pentium !!! up to 1.4GHz (Coppermine &am

Page 5

RS-100-RT User’s Manual 12 System and Environment Construction 19” Rack Mount, Heavy-duty steel chassis, 1U Cooling System 6 15-CFM cooling fans, to

Page 6

RS-100-RT User’s Manual 13 Dimension 426mm (19”) W x 44mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI OS Linu

Page 7 - Contents

RS-100-RT User’s Manual 14 1.2 External Connection SCSI Connector: The serverboard provides a 68-pin Ultra -160 connector for extending SCSI

Page 8

RS-100-RT User’s Manual 15 Printer Port Connector: The serverboard provides a 25-pin female centronic connector for LPT. The parallel port is a standa

Page 9

RS-100-RT User’s Manual 16 1.3 Front Panel 1.3.1 RS-100-RT-S3-S3 Please use a key in accessory box to unlock the front cover. l Front Panel Power

Page 10

RS-100-RT User’s Manual 17 1.4 Rear Panel 64-bit PCI slot port Power Supply 1.5 System Monito

Page 11

RS-100-RT User’s Manual 18 processor thermal sensing and auto-protection. If an alert is triggered, that means a failure status occurs. The system wil

Page 12

RS-100-RT User’s Manual 1 Copyright Notice This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd.

Page 13

RS-100-RT User’s Manual 19 The system provides an optional SNMP MIB-base software that allows user to monitor the current health status of this machin

Page 14

RS-100-RT User’s Manual 20 Chapter 2 System Placement and Installation 2.1 System Placement Power Supply Motherboard FAN

Page 15

RS-100-RT User’s Manual 21 2.2 Motherboard Placement Northbridge RAID Module Connector DIMM Socket LAN Module SCSI Port

Page 16

RS-100-RT User’s Manual 22 The description of jumpers on the motherboard l CN24-Power Bottom / PCI64 33/66MHz Jumper Function Remark 1-2 Close to

Page 17

RS-100-RT User’s Manual 23 PIN 5-6,7-8,9-10 Closed RS-100-RT Two CPU Note2 l J4-RTC CMOS Jumper setting Jumper Function 1-2 Closed RTC CMOS Active

Page 18 - 64-bit PCI slot port

RS-100-RT User’s Manual 24 Note7: CN25---connects to LED board. 2.3 SCSI Backplane Placement 2.3.1 SCA-2 SCSI Backplane l RS-100-RT Connector

Page 19

RS-100-RT User’s Manual 25 (ID 2) 2.4 Installing CPU Before the installation of CPU, please remove the cover of CPU. The server has two Socket

Page 20

RS-100-RT User’s Manual 26 install the CPUs, first turn off your system, remove its cover and follow the directions below that come with the CPUs. Alw

Page 21

RS-100-RT User’s Manual 27 Orient the CPU to the socket correctly so that the pins match the receptacles. Insert the CPU in the socket so that the

Page 22

RS-100-RT User’s Manual 28 2.5 Installing CPU Cooler Fan After a CPU has been installed, you will need to install the proper cooling device for the C

Page 23

RS-100-RT User’s Manual 2 l Adaptec is registered trademark of Adaptec Corporation. l ATI is a trademark of ATI Technologies, Inc. l Serverworks is

Page 24 - 2-3 Closed CMOS Clear

RS-100-RT User’s Manual 29 Place the clip to hold the protrusion on the side of CPU socket. Place the clip to hold the protrusion on a

Page 25

RS-100-RT User’s Manual 30 CPU Cooler Fan installed. Please repeat the same procedure to install another CPU and CPU cooler fan. Please use e

Page 26

RS-100-RT User’s Manual 31 can install any configuration specified in the server specification table. Always observe static electricity precautions wh

Page 27

RS-100-RT User’s Manual 32 Repeat this operation for the rest of modules you will install. Note: Serverworks III LE chipset can support system mem

Page 28

RS-100-RT User’s Manual 33 Remove the pre-installed bracket . And assembly it with add-on card bracket first. Vertically put down the riser card with

Page 29

RS-100-RT User’s Manual 34 2.8 Installing LAN Module The server provides an optional LAN module for the third 10/100Mps LAN. You can buy the L

Page 30

RS-100-RT User’s Manual 35 compliant with IEEE 802.3/u 10/100Mbps CSMA/CD standards. They are supported by all major network operating systems. Three

Page 31

RS-100-RT User’s Manual 36 Insert the zero-channel hardware RAID module into RAID module socket with 30-degree angle. Please press the module

Page 32

RS-100-RT User’s Manual 37 In order to install the hard disk drives in the chassis, please follow the procedures below. Unfasten the dummy HDD tray

Page 33

RS-100-RT User’s Manual 38 Close the latches Slide the cages of the HDD drive into HDD bays and make HDD drive connectors connect the SCSI sockets

Page 34

RS-100-RT User’s Manual 3 Product Warranty Advantech warrants to you, the original purchaser, that each of its products will be free from defects in

Page 35

RS-100-RT User’s Manual 39 2.11 Installing Rail Slider

Page 36

RS-100-RT User’s Manual 40

Page 37

RS-100-RT User’s Manual 41 Chapter 3 BIOS Setup Award BIOS ROM has a built-in Setup program that allows users to modify the basic system configurat

Page 38

RS-100-RT User’s Manual 42 Key Function Description Esc Jump to Exit menu or return to the main menu from sub-menu ↑or ↓ Move the cursor to the up

Page 39

RS-100-RT User’s Manual 43 3.2 Main Menu When the Setup program is accessed, the following screen appears. Move arrow keys to the appropria te place

Page 40 - 2.11 Installing Rail Slider

RS-100-RT User’s Manual 44 3.2.1 Standard CMOS Features Choose the “Standard CMOS Features” option from main menu. The “Standard CMOS Features” allow

Page 41 - RS-100-RT User’s Manual

RS-100-RT User’s Manual 45 IDE Primary Master: Move the highlight to the “IDE Primary Master” and enter to get the following screen. IDE HDD Auto-

Page 42 - Chapter 3 BIOS Setup

RS-100-RT User’s Manual 46 IDE Primary Master: [Auto/Manual/None] Access Mode: [Auto/Large/LBA/CHS]

Page 43

RS-100-RT User’s Manual 47 IDE Primary Slave: Choose the option then get the following three items. IDE HDD Auto-Detection: To auto-detect the capaci

Page 44

RS-100-RT User’s Manual 48 Drive A: Set the type of floppy drive installed by Page Up Key and Page Down. Halt On: Set system halt on when specified

Page 45

RS-100-RT User’s Manual 4 1. Collect all the information about the problem encountered. For example, CPU speed, Advantech products used, other hardwar

Page 46

RS-100-RT User’s Manual 49 3.2.2 Advanced BIOS Features Quick Power On Self Test (POST) [Enabled/Disabled]: Allows the system to skip certain tests

Page 47

RS-100-RT User’s Manual 50 Third Boot Device [Floppy/SCSI/CD-ROM/HDD/LAN/Disabled]: Select your boot device priority Boot Other Device [Enabled/Disab

Page 48

RS-100-RT User’s Manual 51 Typematic Rate (Chars/Sec): BIOS accepts the following input values (characters/second) for typematic rate: 6, 8, 10, 12, 1

Page 49

RS-100-RT User’s Manual 52 3.2.3 Integrated Peripheral On-Chip Primary PCI IDE [Enabled/Disabled]: The system provides an onboard on-chipset PCI ID

Page 50

RS-100-RT User’s Manual 53 IDE Primary Master/Slave UDMA [Auto/Disabled] On-Chip Secondary PCI IDE [Enabled/Disabled] IDE Secondary Master/Slave PIO

Page 51

RS-100-RT User’s Manual 54 Onboard Serial Port 2 [Auto/Disable/(3F8/IRQ4)/(2F8/IRQ3)/(3E8/IRQ4)/(2E8/IRQ3)] The system has an On-board Super I/O chip

Page 52

RS-100-RT User’s Manual 55 3.2.4 PnP/ PCI Configurations PnP OS Installed [Yes/No]: Select “Yes” if you are using a Plug and Play enabled operating

Page 53

RS-100-RT User’s Manual 56 automatically assigns them. PCI/VGA Palette Snoop [Disabled/Enabled]: Some display cards that are nonstandard VGA, such a

Page 54

RS-100-RT User’s Manual 57 3.2.5 Load Optimized Defaults The option allows you to load the optimized default values for each of the parameters on t

Page 55

RS-100-RT User’s Manual 58 3.2.6 Set Password The option allows you to set or change user password. To set the user password, press “Enter”. Type pas

Page 56

RS-100-RT User’s Manual 5 Packing List You should find the items listed below in the server package. If anything is missing or damaged, please consul

Page 57

RS-100-RT User’s Manual 59 3.2.7 Save & Exit Setup Once you finish your selection, choose the option to save the values you selected to CMOS RAM.

Page 58

RS-100-RT User’s Manual 60 3.2.8 Exit without Saving The option should only be used if you do not want to save the changes you have made to the Setup

Page 59

RS-100-RT User’s Manual 61 Chapter 4 Drivers Installation The servers support several Operating Systems including Microsoft Windows NT 4.0/ 2000, L

Page 60

RS-100-RT User’s Manual 62 4.1 Drivers for Windows NT 4.0 In the CD disc for Driver Bank, there are some options as below when running “Setup” or CD a

Page 61

RS-100-RT User’s Manual 63 shown on the screens. Restart after driver installation. l Installing SCSI driver for Windows NT 4.0 Driver Install duri

Page 62

RS-100-RT User’s Manual 64 RS100_200_rf\82559\LAN – Drivers for Windows NT 4.0, RS200-RT\broadcom – Drivers for Windows NT 4.0 l Zero-channel RAI

Page 63

RS-100-RT User’s Manual 65 For more information about how to setup RAID, please retrieve the file RAID_USER_GUIDE.PDF located in the subdirectory RS-

Page 64

RS-100-RT User’s Manual 66 4.2 Drivers for Windows 2000 l VGA driver installation Please select the item “RS100/ 200-RT Drivers”. Please click

Page 65

RS-100-RT User’s Manual 67 l Adaptec I2O RAID Host Adapter Driver for Windows 2000 Driver setup during Windows 2000 Installation 1. CD-ROM Install:

Page 66

RS-100-RT User’s Manual 68 l Install LAN Driver Please go to the following subdirectory when system requests LAN driver during OS installation. R

Page 67

RS-100-RT User’s Manual 6 Contents Chapter 1 Introduction ------------------------------ 9 1.1 Specifications ----------------------------------

Page 68

RS-100-RT User’s Manual 69 4. When it shows “ Insert your driver disk”, please press “OK”. 5. Then, follow the instructions showed on the screens. F

Page 69

RS-100-RT User’s Manual 70

Page 70

RS-100-RT User’s Manual 71 Appendix A Memory Approval List Module Vendor Module Part No. Chips Vendor Memery Size ATP AR16V72C4S4GAS SAMSUNG 128M

Page 71

RS-100-RT User’s Manual 72 Appendix B. Giga bits LAN Card approval list Card Vendor Card Part No. Chip Part No. Intel Intel PRO/1000T Server Adap

Page 72

RS-100-RT User’s Manual 73 Appendix C. RAID Card Approval List Card Vendor Card Part No. Speed type. Adaptec SCSI RAID 3000S PCI64 bits / 66MHz (D

Page 73

RS-100-RT User’s Manual 74 Appendix D Accessory order information No. P/N Description 1 9686000073 ZCR HW RAID module 2005S 2 96960210A0 LAN mo

Page 74

RS-100-RT User’s Manual 75 Appendix F Safety Instructions F.1 English 1. Read these safety instructions carefully. 2. Keep this user’s manual for lat

Page 75 - Appendix E ZCR RAID Utility

RS-100-RT User’s Manual 76 service personnel. a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has

Page 76

RS-100-RT User’s Manual 77 F.2 German- Wichtige Sicherheishinweise 1. Bitte lesen Sie Sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleit

Page 77

RS-100-RT User’s Manual 78 elektrischen Schlag auslösen. 13. Öffnen Sie niemals das Gerät. Das Gerät darf aus Grnden der elektrischen Sicherheit nur

Page 78

RS-100-RT User’s Manual 7 3.2 Main Menu -------------------------------------- 43 3.2.1 Standard CMOS Features ---------------- 44 3.2.2 Advanced

Page 79

RS-100-RT User’s Manual 8

Comments to this Manuals

No comments