45 PCM-3362 User Manual
Chapter 4 Software Introduction & Installation
Click the radio button- Access a byte.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Click the READ SMBus DATA button and a byte of data from the device will
be shown on the Result field.
Write a byte
Click the radio button- Access a byte.
Key in the slave device address in Slave address field.
Key in the register offset in Register Offset field.
Key the desired data in the Result field to write to the device.
Click the WRITE SMBus DATA button and then the data will be written to the
device through SMBus.
Read a word
Click the radio button- Access a word.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Click the READ SMBus DATA button and then a word of data from the device
will be shown on the Result field.
Write a word
Click the radio button- Access a word.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Key in the desired data, such as 0x1234, in the Result field to write to the
device.
Click the WRITE SMBus DATA button and the data will be written to the
device through the SMBus.
Read Multiple bytes
Click the radio button- Access multiple bytes.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Key in the desired number of bytes, such as 3, in the right side field of radio
button- Access multiple bytes. The number must be written in decimal.
Click the READ SMBus DATA button and then all data from the device will be
divided from each other by commas and be shown in the Result field.
Write Multiple bytes
Click the radio button- Access multiple bytes.
Key in the slave device address in the Slave address field.
Key in the register offset in the Register Offset field.
Key in the desired number of bytes, such as 3, in the right side field of the
radio button- Access multiple bytes. The number must be written in decimal.
Key in all the desired data in the Result field in hexadecimal format, divided
by commas, for example, 0x50,0x60,0x7A.
Click the WRITE SMBus DATA button and all of the data will be written to the
device through the SMBus.