Isolated Digital Output
Each of the 32 isolated digital output channels comes equipped with a darlington
transistor. Every eight ouput channels share common emitters and integral suppres-
sion diodes for inductive load, activated by connecting PCOM to VDD. (Channels 0 ~
7 use PCOM0. Channels 8 ~ 15 use PCOM1. Channels 16 ~ 23 use PCOM2. If the
external voltage source (5~40 V) is connected to each isolated output channel (IDO)
and its isolated digital output turns on (200 mA max./ch), the card's current will sink
from the external voltage source. The current through EGND should not exceed 4.8
A. If the current for all channels combined exceeds 2 A, CN2 must be connected to
the external ground to share the extra current. The following figure shows how to
connect an external output load to the card's isolated outputs.
Figure 3.9 Isolated Digital Output Connection
Internal External
IDO0
IDO1
IDO2
IDO3
IDO4
IDO5
IDO6
IDO7
EGND
Isolated
Circuit
PCOM
Relay
NO
NC
Common
Diode
VDD
5~40V