27 Chapter 4 Alarm Module
4.2.2 Switch Settings
The alarm board is designed to connect with up to 7 fans. Users can set
the fan number by adjusting the switch, SW1, on the alarm board.
4.3 Thermal Sensor
The ACP-4010 is configured with a thermal sensor located at the rear
plate of the chassis. (see Figure 4.2)
Figure 4.2: Thermal sensor location
Table 4.11: SW1, Fan number setting
Fan Number SW 1-1 SW 1-2 SW 1-3 SW 1-4
0 OFF OFF OFF OFF
1ONOFFOFFOFF
2 (default) OFF ON OFF OFF
3ONONOFFOFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7ONONONOFF
Note: Please connect the fan connectors in the correct sequence: If two
fans are set on SW1, the correct method to connect them into connectors
FAN1 and FAN2. If the two fans are connected to other fan connectors,
out of sequence, such as FAN1 and FAN3 or FAN2 and FAN3 or FAN3
and FAN4, then the alarm will not function correctly.
Thermal sensor